How heat pumps work is easier to understand when you stop picturing a machine that makes warmth by burning fuel. A standard electric heat pump moves heat from one place to another. In winter, it gathers thermal energy from outdoor air or the ground and delivers it indoors; in summer, it can reverse direction to move indoor heat outside. Electricity runs the compressor, fans and controls, but the main heating process is heat transfer rather than electric resistance or combustion. That distinction explains why a heat pump can still warm a home when the outdoor air feels cold, while also explaining why its output may change as conditions get harsher.

The basic cycle: collect heat, raise its temperature, move it indoors

In a typical air-source system, a refrigerant circulates through an outdoor coil, a compressor, an indoor coil and an expansion device. In heating mode, the cold refrigerant in the outdoor coil absorbs heat from the outside air and evaporates. The compressor uses electricity to pressurize the vapor, raising its temperature. Indoors, the hotter refrigerant releases heat into the home’s air or water, then cools and returns through the cycle. The refrigerant’s boiling point changes with pressure, allowing the system to collect heat at a low temperature and release it at a higher one. According to the U.S. Department of Energy’s air-source heat-pump guide, the system circulates refrigerant between indoor and outdoor coils; a reversing valve changes the direction of flow for cooling and the winter defrost cycle.

This is not heat creation from nothing. The pump needs electricity to move heat and overcome the temperature difference between its source and the room. When outdoor conditions are milder, the system generally has less work to do to bring heat up to indoor temperature. As the air gets colder, the temperature “lift” becomes more demanding, and many systems deliver less heating capacity or operate less efficiently. The exact change depends on the equipment, installation, controls and conditions. “It is cold outside” therefore does not mean “there is no heat to collect,” but neither does the basic principle promise unchanged output at every temperature.

Air outside or heat stored in the ground?

An air-source heat pump exchanges heat with outdoor air through a unit mounted outside the building. It can connect to existing ducts, serve rooms through ductless indoor heads, or in some designs circulate heated water. Because it uses the air as its source, its operating conditions track the weather more directly. Cold-climate models are designed and tested for improved performance at low outdoor temperatures. ENERGY STAR explains that its cold-climate certification includes third-party performance testing at 5°F; that benchmark is not a claim that every model has identical output or that the system stops working below that point. ENERGY STAR says cold-climate units can continue operating below 5°F, while the need for backup depends on the home and system. See its cold-climate air-source heat-pump guidance for details.

A ground-source, often called geothermal, heat pump exchanges heat with the shallow ground through buried pipes or another ground heat exchanger. The loop may be arranged horizontally in trenches, vertically in drilled boreholes, or in a suitable pond or lake; some systems use an open loop. According to DOE’s geothermal heat-pump overview, shallow ground temperatures are more stable through the seasons than outdoor air in many places. That steadier source can reduce the system’s exposure to sharp air-temperature swings, but it does not remove the need for a properly designed heat pump, indoor distribution and site-specific ground loop. Space, soil, water conditions, drilling or excavation, local requirements and the building’s heating needs all matter.

The two types share the same heat-moving principle but draw from different sources. An air-source unit takes heat from ambient air at the outdoor coil; a ground-source unit transfers heat through a buried or submerged loop. The ground system’s steadier source is a technical difference, not a universal verdict about which setup suits a particular house. The building, local climate, available land, existing ducts or emitters, installation constraints and intended use can change what matters most. Neither label alone tells a reader what the indoor temperature will feel like during a specific cold spell.

Why cold-weather operation can include defrost or backup heat

In humid, chilly weather, frost can build up on an air-source heat pump’s outdoor coil and interfere with heat exchange. Many systems periodically enter a defrost cycle to clear that frost. DOE notes that the reversing valve changes refrigerant flow for the winter defrost cycle. During defrost, the outdoor coil is warmed; depending on the system and controls, heating delivered indoors may pause or be supplemented for a short time. A brief change in fan sound, steam or water around the outdoor unit can occur during normal operation, but persistent ice, repeated comfort problems or unusual operation call for the equipment manual or a qualified service professional rather than guesswork.

Some homes also use backup heat. In an all-electric setup, auxiliary resistance elements may help when the heat pump cannot meet the home’s heating load quickly enough. A dual-fuel arrangement pairs the heat pump with a furnace that can take over or assist under selected conditions. Not every system has the same backup, and some designs rely on a heat pump without a separate source. The switch or “balance point” depends on the heat pump’s available capacity, the home’s heat loss and system controls; it is not one universal outdoor temperature. DOE’s guidance on air-source performance and selection describes the point at which a home’s heating load can exceed a particular pump’s capacity, making auxiliary heat relevant.

Field testing also shows why the conditions and system details matter. A DOE-funded National Renewable Energy Laboratory study monitored variable-capacity air-source heat pumps in 12 cold-climate homes over winter seasons. Researchers tracked operating modes including compressor heating, auxiliary heating and defrost, alongside capacity and electricity use. That study is evidence that actual winter operation includes more than a single headline efficiency number; it is not a guarantee for every product, house or climate.

What readers should check before drawing conclusions

If you are trying to understand a system already in a home, first identify whether it is air-source or ground-source, whether it has ducts or ductless indoor units, and whether backup heat is installed. Check the thermostat or owner’s manual for the system’s heat, emergency-heat and auxiliary-heat settings before changing modes. For an outdoor unit, keep the air path clear of snow, leaves and stored items, and follow the manufacturer’s instructions for filters and routine care. DOE’s maintenance guide highlights filter, airflow, coil and professional-service checks. Do not chip ice from a coil or open equipment panels unless the manufacturer explicitly says it is safe.

For a high-level comparison of a proposed system, look beyond the nameplate’s mild-weather rating. Ask what heating capacity the specific model is expected to provide at the local winter design temperature, how that compares with the home’s calculated heat loss, and how defrost and backup heat are controlled. ENERGY STAR recommends that homes in regularly freezing climates consider a certified cold-climate air-source model suited to the home, and points to proper sizing as essential. A contractor’s load calculation, duct or radiator suitability, insulation and air leakage, and the location of an outdoor unit can all affect real-world comfort. For a ground-source system, ask what loop layout and site conditions the design assumes, and whether local permits or drilling rules apply. These questions help clarify the trade-offs without assuming a particular technology will fit every home.

The short answer to how heat pumps work is that they use electricity to transfer existing heat, not to create warmth through combustion or resistance heating. Air-source and ground-source systems differ mainly in where they collect that heat, and colder weather can change how much capacity is available and whether defrost or backup heat is used. Understanding those basics makes it easier to interpret performance claims, operating sounds and system specifications without treating any one number as a guarantee. For another guide to household electricity use, see GenZ NewZ’s standby-power explainer, which covers small continuous loads rather than space heating.